Horizontal Rectangular H.P. Steam Sterilizer GGT-103LCD

G.G.Technologies® Manufacturer of Hospital, Institute, Industries, Agriculture, Pharmaceutical lab Testing Equipment’s HORIZONTAL RECTANGULAR H.P. STEAM STERILIZER MODEL NO. GGT -103/LCD

Availability: In Stock
Enquire on WhatsApp
Category:
Description

ZEXTER HORIZONTAL RECTANGULAR H.P. STEAM STERILIZER (MODEL NO. GGT-103/LCD)

G.G.Technologies
LAB SOLUTION – Manufacturer of Hospital, Institute, Industries, Agriculture, Pharmaceutical lab Testing Equipment’s

Horizontal Autoclave High Speed Steam Sterilizer Fully Automatic Rectangular – made SS 304 with electric load 18kw digital time and temperature controller also.

GENERAL FEATURES

  1. Fitted with Microprocessor Based Fully Automatic Fuzzy Logic Control System with Alphanumeric Digital backlit LCD display with Set Value (SV) and Process Value (PV).
  2. Unit is fitted with water level indicator, safety valve, pressure gauge, water inlet and drain valves.
  3. Unit is also fitted with low-water level cut-off device and automatic pressure control device.
  4. All rectangular sterilizers are fitted with SELF LOCKING SAFETY DOOR device. The door cannot be opened when chamber is under pressure.
  5. Two separate valves are provided for evacuating steam from inner chamber and jacket, as and when desired.
  6. Fitted with safety valve as a safety device.
  7. Drain valve is fitted at the side bottom for easy draining/cleaning.
  8. Fitted with vacuum breaker to break vacuum in case of formation of vacuum due to steam condensation.
  9. Triple Walled with Steam Jacket and Separate Boiler. Sterilization cycle is controlled by Multiport Valve. The unit is fitted with all standard accessories.
  10. PLC feature: Automatic features (steam in, steam out, vacuum & pre vacuum).
  11. Vacuum Pump: High water ring Kirloskar 3 hp pump for high vacuum.
  12. Water Fill up pump: For fill water automatically with motor Crompton 1 hp.

SALIENT FEATURES

Component Specification
Inner Chamber Built with AISI 304 grade 6mm stainless steel
Jacket Built with AISI 304 grade 6mm stainless steel
Boiler Tank Built with AISI 304 grade 4mm stainless steel
Heavy Duty Stand Built with AISI 304 grade 10mm stainless steel
All Pipe Line Makes Built with AISI 304 grade 16mm stainless steel
Outer Cover Built with AISI 304 grade 1.5mm stainless steel
Main Door Heavy duty jointless SS-304 grade 10mm
Back Sheet (Chamber) Heavy duty jointless SS-304 grade 8mm
Strong Argon arc welded For greater durability
Double Door Optional

WORKING CYCLE

  1. Available in three cycle types.
  2. Standard speed working pressure (121°C).
  3. High speed working pressure (134°C) (1.2 kg) to (2.5 kg).
  4. As per your requirement.

TEST MODE

  1. Leak Test Mode
  2. Vacuum Leak Test
  3. Chemical Indicators
  4. Biological Indicators
  5. The bowie-dick test
  6. (All features can be controlled by manual mode also)

SAFETY FEATURES

Feature Specification / Function
Self-locking Safety Door Gasket Under pressure and heat-resistant SILICON door gasket.
Water Level Gauge Glass Show water level with sensor
Spring Safety Valves In jacket for over pressure protection.
Weight Safety Valve In jacket for over pressure protection.
Pressure Switch For power consumptions. And pressure cut off
Low Water Protection To protect electric heaters.
Earth Safety System For safety of operator and machine
Steam Deflector For better vacuum and dryness
Air Vent / Steam Trap Moisture trap
Pressure Gauge For show of steam pressure jacket

COMPLIES WITH THE FOLLOWING

  1. NABH TEST PASS
  2. THE BOWIE-DICK TEST is a standard operational test by which hospitals and laboratories can demonstrate proper air removal from their pre-vacuum autoclave chamber. It is primarily useful for testing pre-vacuum cycles that are sterilizing wrapped goods or packs.
  3. BIOLOGICAL INDICATORS (WITHIN A PCD) are often used for routine monitoring, qualification and load monitoring of a steam sterilizer. Biological indicators are designed to demonstrate whether the conditions during a steam (autoclave) cycle were adequate to achieve a defined level of microbial inactivation.
  4. THE VACUUM LEAK TEST is used to determine the air-tight integrity of a pre-vacuum autoclave’s chamber and plumbing system. This test exposes the autoclave’s plumbing and components to vacuum conditions and measures how much vacuum depth was lost over a given period of time.
  5. CHEMICAL INDICATORS are used to monitor whether the parameters to achieve sterilization have been met for a specific sterilization process, such as steam or vaporized hydrogen peroxide sterilization.

MODEL & TECHNICAL SPECIFICATIONS

MODEL INNER DIMENSIONS (WXHXD) in mm CAPACITY HEATER LOAD OPERATING PARAMETERS
GGT-103/LCD180L 450 x 450 x 900 180 ltrs 6.0 KW 15-20 psi at 121°C OR 30 psi at 134°C
GGT-103/LCD240L 450 x 600 x 900 240 ltrs 9.0 KW 15-20 psi at 121°C OR 30 psi at 134°C
GGT-103/LCD320L 600 x 600 x 900 320 ltrs 9.0 KW 15-20 psi at 121°C OR 30 psi at 134°C
GGT-103/LCD430L 600 x 600 x 1200 430 ltrs 9.0 KW 15-20 psi at 121°C OR 30 psi at 134°C
GGT-103/LCD810L 600 x 900 x 1500 810 ltrs 18.0 KW 15-20 psi at 121°C OR 30 psi at 134°C
GGT-103/LCD1260L 900 x 900 x 1500 1260 ltrs 24.0 KW 15-20 psi at 121°C OR 30 psi at 134°C

OPTIONS

  1. Automatic water feed system can be incorporated in the boiler, so that at higher level it switches off the water pump and restarts it at lower level automatically.
  2. Vacuum pulsing through a closed coupled water ring high vacuum pump for creating forced vacuum and fast drying process.
  3. TFT Touch Screen Display Controller in lieu of LED / LCD Controller.
  4. Printer Port cost extra.