Features
- Aerodynamic airflow grills maintain safety and prevent blockage.
- Air drawn through pre-filter passes through highly effective HEPA filters having efficiency ratings as high as 99.99% with cold DOP and 99.99% with hot DOP, retaining all airborne particles of size 0.1 micron and larger.
- The highly efficient HEPA/ULPA filter maintains optimum cleanliness and purity.
- Being equipped with a pre-filter, it extends the life of the HEPA/ULPA filter.
- 30% air exhaust.
- 70% air recirculation.
- HEPA filtered exhaust air in Type A1 cabinet may be recirculated into the room or exhausted outdoors through a canopy exhaust connection.
- HEPA filtered downflow air is a portion of mixed downflow and inflow air from a common plenum.
- U.V. and fluorescent interlock available.
- Ergonomic 10° sloped front window provides comfortable head and elbow rest positions, reducing fatigue.
- Sash is counterbalanced for smooth and lightweight operation with a standard opening of 200 mm ±10 mm for easier access and enhanced user safety.
Class-II Type A1 Biosafety Cabinet Protection
- Personnel protection from harmful agents used inside the biosafety cabinet.
- Product protection to avoid contamination of work, experiments, or processes from outside contaminants.
- Environmental protection from contamination of work, experiments, or processes.
Class-II Type A1 Biosafety Cabinet Key Features
- Front access opening with carefully maintained inward airflow.
- HEPA filtered, vertical, unidirectional airflow within the work area.
- HEPA filtered exhaust air to the room or to a facility exhaust system.
Class-II Type A1 Biosafety Cabinet Applications
- Type A1 cabinets are typically used for Biosafety Levels 1 through 3.
- Suitable for work with chemicals, provided vapors are not hazardous and do not interfere with the work when recirculated.
- Can be used with small amounts of chemicals when the cabinet is exhausted outdoors (optional configuration).
| Type A1 |
|---|
| Type A1 |
| Personnel, Work Area (Product) and Environment |
| If exhausted to facility exhaust system, protects personnel If exhausted to a treated facility (VIRUS BRUN OUT) exhaust System protects personnel, the work area and the Environment. |
- Upper & Front Cover:
Removable upper and front cover simplifies filter, blower, and front control panel replacement and makes maintenance easier. - Material of Construction:
- Internal working table is made of Stainless Steel (SS-304).
- External cabinet is fabricated from SS-304 Steel or MS duly powder coated.
- Front Window / Sash:
Front sash consists of thick plexiglass or optional toughened transparent glass for a clear interior view. It provides optimum resistance and protection against harmful UV rays, protecting users from ultraviolet radiation exposure. - Drain Trough with Valve:
The trough at the base is easy to clean and allows safe drainage of any liquid spillage. - Decontamination by UV Lamp:
UV lamp produces UV rays of 253.7 nm. The UV lamp and fluorescent lamp are interlocked, and the motor blower automatically turns off/on when the front sash is closed/opened. An optional timer controls the decontamination cycle, maximizes UV lamp life, and automatically switches the fluorescent lamp on after the cycle is completed. - Splash Proof Electric Supply Socket:
Splash-proof sockets are provided for convenient use of small electrical devices inside the cabinet. - Front Airflow Intake Grid:
Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination. - Floor Stand and Castor Wheels:
Heavy-duty tubular powder-coated floor stand fitted with durable castor wheels for smooth movement and a total brake system on the front wheels.
| Class II Type A1/A2 Biological Safety Cabinet Model | BSC-II-A1 222 (2A2) | BSC-II-A1 322 (3A2) | BSC-II-A1 422 (4A2) | BSC-II-A1 522 (5A2) | BSC-II-A1 622 (6A2) |
|---|---|---|---|---|---|
| Internal Dimensions (W×D×H) mm | 600 × 600 × 600 | 900 × 600 × 600 | 1200 × 600 × 600 | 1500 × 600 × 600 | 1780 × 600 × 600 |
| Working Area (ft.) | 2 × 2 × 2 | 3 × 2 × 2 | 4 × 2 × 2 | 5 × 2 × 2 | 6 × 2 × 2 |
| MOC | Internal Working Chamber: Stainless Steel (SS-304) Exterior Cabinet: Stainless Steel (SS-304) |
||||
| Pre-Filter | Mounted on aluminium frame, rating 20 microns | ||||
| Supply / Main Filter | HEPA/ULPA (Efficiency 99.99% @ 0.1 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, Class 10) | ||||
| Exhaust Filter | HEPA (Efficiency 99.99% @ 0.1 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, Class 10) | ||||
| Power Supply | 220 V / 50 Hz (Standard) | ||||
| Exhaust Connector (Option) | To exhaust potentially contaminated air outside the room | ||||
| Exhaust Tunnel / Duct (Ø150 mm) (Option) | Available on per running basis | ||||
| Sash Lift | Can be lifted and adjusted manually | ||||





Reviews